Approx. 100 projects in 2014
- Client
- worldwide
- Country
- Worldwide
Boilers, components and piping for power engineering and industry – summary of projects completed in the given year.
We successfully implement coal-fired thermal power equipment using VCFV (high-temperature circulating fluidized bed) technology, achieving excellent technical and economic results based on thorough study and research. Research into the operation and principles of the coal combustion process in VCFV was carried out using mathematical modelling of these processes and comparison of these models against existing VCFV boilers.
We now offer a whole range of proven, reliable VCFV furnaces and boilers with an output from 1 to 50 MW and higher (capacities of up to 180 MW are available).
Many years of successful operation of VCFV boilers under real boiler-house conditions have refuted the widespread belief that fluidized bed technology is unsuitable for industrial power engineering because of its complexity and high implementation costs. VCFV technology requires no special expensive equipment and is fully adaptable to most domestic boilers at minimal cost. A bed of suitable height is formed without an inert material charge, thanks to the fuel's own ash, and operates on a moving ribbed grate, which externally resembles a narrow, inclined layer-fired furnace. When existing boilers are refurbished, the main technological equipment is generally retained. The combination of the advantages of VCFV and the principle of burning fuel on a moving grate (as in layer firing) has a number of benefits, both in terms of boiler operating reliability and in terms of quickly mastering the new technology.
| Calorific value, kcal/kg | Qph | 7082÷1556 |
|---|---|---|
| Ash content, % | Ap | 10,3÷36,7 |
| Moisture content, % | Wp | 8,0÷55,2 |
| Volatile matter content, % | Vr | 11,6÷70,0 |
| Fraction composition (grain size), mm | – | 0-13÷0-50 |
| Boiler type | Hot-water boiler 17.5 MW | Steam boiler 10 t/h | Hot-water boiler 35 MW | |||
|---|---|---|---|---|---|---|
| Combustion type | VCFV | layers | VCFV | layers | VCFV | layers |
| Fuel | hard coal blend | Neryungri hard coal | Montenegrin coal screenings | |||
| Operating gross efficiency, % | 83-86 | 70-76 | 85-87 | 73-76 | 84-87 | 72-77 |
| Load turndown range, % of Dnom | 20-150 | 50-80 | 20-150 | 40-100 | 20-150 | 50-80 |
| Fly ash emissions, μg/m3 | 1,5-2 | 12-15 | 1,5-2 | 12-15 | 1,5-2 | 12-15 |
| Nitrogen oxide NOx emissions, mg/m3 | 150-200 | 300-400 | 200-240 | 300-400 | 145-200 | 300-400 |
In the construction and refurbishment of boilers we cooperate with the company "Petrokotel-VCFV". The team of "Petrokotel-VCFV" is currently the main development group focused on boiler development in Russia. The equipment is manufactured in the Russian Federation and Ukraine. The main manufacturer of VCFV furnaces is the company CHENKO-BUD.
VCFV boilers burn practically any solid fuel: hard and brown coal, their fines, and wood waste.
| Calorific value, kcal/kg | Qn | 7082÷1556 |
|---|---|---|
| Ash content, % | Ap | 10,3÷36,7 |
| Moisture content, % | Wp | 8,0÷55,2 |
| Volatile matter content, % | Vr | 11,6÷70,0 |
| Fraction composition (grain size), mm | – | 0-13÷0-50 |
| Boiler type | Hot-water boiler 17.5 MW | Steam boiler 10 t/h | Hot-water boiler 35 MW | |||
|---|---|---|---|---|---|---|
| Combustion type | VCFV | layers | VCFV | layers | VCFV | layers |
| Fuel | hard coal blend | Neryungri hard coal | Montenegrin coal screenings | |||
| Operating gross efficiency, % | 83-86 | 70-76 | 85-87 | 73-76 | 84-87 | 72-77 |
| Load turndown range, % of Dnom | 20-150 | 50-80 | 20-150 | 40-100 | 20-150 | 50-80 |
| Fly ash emissions, μg/m3 | 1,5-2 | 12-15 | 1,5-2 | 12-15 | 1,5-2 | 12-15 |
| Nitrogen oxide NOx emissions, mg/m3 | 150-200 | 300-400 | 200-240 | 300-400 | 145-200 | 300-400 |
Combining the advantages of VCFV with the principle of fuel combustion on a moving grate (as well as on a layered one) has a number of benefits, both in terms of boiler operating reliability and in how quickly the new technology can be mastered.

When burning low-grade coal, VCFV technology delivers a gross efficiency that is practically unattainable in series-produced boilers using bed combustion, and with higher-quality fuel, increased efficiency is additionally guaranteed. The time-proven reliability of VCFV boilers allows their use in steam production for driving turbines and in the development of independent small thermal power plants and heating plants.
Operational agility, flexibility, and a comprehensive approach to the technological solution are the main benefits of cooperating with our company in thermal power engineering.
Thanks to modern fluidized and circulating bed technologies (VCFV), we are able to successfully solve the problem of efficiently burning lower-quality fuels as well.
Benefits of reconstructions to create combined boilers:
compliance with environmental limits for emissions of harmful pollutants into the air

Phases of boiler reconstruction for bed combustion of fuel:
Principle of boiler reconstruction and transition to VCFV technology:
During reconstruction, VCFV technology makes it possible to retain practically completely the traditional boiler design, the slag and ash removal system, and the automation, which significantly reduces the overall cost of the work. The boiler location does not change during reconstruction; it stays in its old place and auxiliary equipment is not affected.
Conventional bed furnaces require pneumatic-mechanical spreaders to distribute the fuel evenly over the entire area of a wide grate (one of the least reliable mechanisms).
Because combustion in VCFV takes place on a narrow grate, VCFV boilers are equipped with simple pneumatic-gravity feeders without spreaders for fuel supply. The fluidized bed itself distributes and mixes the fed fuel evenly.
| Before reconstruction | After reconstruction | Weight change | |
| Weight of furnace together with feeder and drive, t | 27,0 | 12,0 | -15,0 |
| Weight of tube system, t | 41,2 | Extension of: - two side tube walls; - front tube wall; - rear furnace tube wall - water-supply tubes | +2,0 +1,0 +1,3 +1,0 |
| TOTAL: boiler weight change, t | -9,7 |


Operation of boilers with VCFV furnaces does not place demanding requirements on the qualification of operating personnel and practically does not differ from standard bed-combustion boilers; it requires no special training, and brief on-the-job instruction is sufficient.
The use of solid-fuel combustion technology in a high-temperature circulating fluidized bed (VCFV) has in recent years been expanding in industrial power engineering as well, thanks to the possibility of using a very wide range of cheap local low-grade fuel.
For fuels with a particularly high content of components that generate harmful emissions and cause heavy air pollution, we are able (given the strict requirements for maximum permissible emissions of harmful substances) to include additional deep flue gas cleaning measures in the project.
References

Boilers, components and piping for power engineering and industry – summary of projects completed in the given year.

Boilers, components and piping for power engineering and industry – summary of projects completed in the given year.

Boilers, components and piping for power engineering and industry – summary of projects completed in the given year.